10 - 18 Symbol MiniScan MSXX04 Series Integration Guide

Timeout Between Decodes

Timeout Between Decodes, Same Symbol

Parameter # 89h

When in Continuous triggering mode, this parameter sets the minimum duration of not decoding data before the
scanner decodes a second bar code identical to one just decoded. This reduces the risk of accidently scanning the
same symbol twice. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended
interval is 0.6 seconds.

Timeout Between Decodes, Different Symbol

Parameter # 90h

This option sets the minimum duration of not decoding data before the scanner decodes a second (different) bar
code. This is used in continuous-on mode to prevent the beeper from beeping when a different symbol appears in
the scanner’s field of view before the timeout period between decodes expires. This is programmable in 0.1 second
increments from 0.0 to 9.9 seconds. The recommended value is 0.0 seconds.

Select the timeouts between decodes for the same or different symbols.

1.

Scan the option bar code you wish to set.

2.

Scan two numeric bar codes beginning on

page 10-111

which correspond to the desired interval, in 0.1 second

increments.

To change the selection or to cancel an incorrect entry, scan the

Cancel

bar code on

page 10-113

.

Timeout Between Decodes -

Same Symbol

Timeout Between Decodes -

Different Symbols