Ucc supplemental options – Metrologic Instruments MS951 User Manual
Page 39

*
*
R
5
2
R
5
3
R
7
0
R
7
1
S
P
1
S
P
2
S
P
3
S
P
4
S
P
5
S
P
6
S
P
7
S
P
8
Enter/Exit Program Mode
34
Convert EAN-8 to EAN-13
When this option is selected, the scanner will
convert EAN-8 to EAN-13 by transmitting
five zeroes before the bar code.
** Do Not Convert EAN-8 to EAN-13
Enable “$” Prefix ID for UPC/EAN
** Disable “$” Prefix ID for UPC/EAN
UCC Supplemental Options
Enable 2 Digit Supps
When this option is enabled, the scanner will scan 2
digit supplementals.
** Disable 2 Digit Supps
Enable 5 Digit Supps
When this option is enabled, the scanner will scan 5
digit supplementals.
** Disable 5 Digit Supps
Enable Bookland
When this option is enabled, the scanner will
require that a 5-digit supplement be scanned
whenever an EAN-13 code begins with 978.
** Disable Bookland
Supplement Required
When this option is selected, all UPC/EAN labels
that are scanned must have a supplement.
** Supplement Not Required