Laser activation range, Laser operation – Metrologic Instruments MS951 User Manual

Page 9

Advertising
background image

*

*

R

S

1

R

S

3

R

S

2

R

S

4

R

S

5

R

S

6

L

P

8

Enter/Exit Program Mode

4

Laser Activation Range

Short Range Activation

When this option is selected, the IR sensor

Out of the Stand

is guaranteed to be activated when the posi-
tion of the scanning window three inches from
the object.

Short Range Activation

When this option is selected, the IR sensor

In the Stand

is guaranteed to be activated when an object is
presented three inches from the scanning
window.

**Long Range Activation

When this option is selected, the IR sensor

Out of the Stand

is guaranteed to be activated when the posi-
tion of the scanning window is eight inches
from the object.

**Long Range Activation

When this option is selected, the IR sensor

In the Stand

is guaranteed to be activated when an object is
presented eight inches from the scanning
window.

Laser Operation

** Normal Scan

This option is the default setting. When the laser is
activated by the IR sensor, the laser beam emits from the
output window and displays a constant, horizontal line
until a bar code is sensed or until the scanner timeout
elapses.

Pulsing Scan

When the laser is activated by the IR sensor, the laser
beam emits from the output window and displays a
horizontal line that pulses until a bar code is sensed or
until the scanner timeout elapses.

Custom Scan

This option is available for special applications.

Do not

scan the CUSTOM SCAN bar code unless

instructed by a Metrologic representative.

Advertising