Itf minimum symbol length test, Msi plessey check digit – Metrologic Instruments MS951 User Manual

Page 47

Advertising
background image

*

*

R

0

2

R

0

3

R

0

4

R

0

5

R

0

6

R

B

C

R

B

D

Enter/Exit Program Mode

42

ITF Minimum Symbol Length Test

A custom minimum character length can be configured for only ITF bar
codes. This leaves shorter minimum lengths for other code types possible. The
scanner will not scan codes with fewer than the configured minimum of
characters. To activate, first scan an ITF character lock length. Then scan
RBC-enable minimum test. This feature overrides ITF character locking.

Enable ITF Minimum
Symbol Length Test

Disable ITF Minimum
Symbol Length Test

MSI Plessey Check Digit

Enable MSI Plessey

When this option is enabled, the scanner will

scan MSI Plessey bar codes.

** Disable MSI Plessey

**Enable MSI Plessey Test of Check Digit

When this option is enabled, the scanner will
check the MSI Plessey bar code for a proper
check digit.

Disable MSI Plessey Test of Check Digit

**Enable MSI Plessey

When this option is enabled, the scanner will

Mod 10 Check Digit

scan

MSI Plessey bar codes that have a single

Modulo 10 check digit.