Miller Electric Miller DU-OP User Manual

Page 22

Advertising
background image

OM-494 Page 18

5-8. Making Dual Operator CC Weld Connections w/ Separate Work Cables

Ref. 190 377 / 802 292-A

Y Stop engine.
Y Do not exceed machine duty cycle.

.

Use Dual Operator mode for CC and
CV welding (see Section 6-1
).

See Section 5-15 for proper cable size.
1

Strain Reliefs

Route cables through strain reliefs.

2

Electrode Holder Cables

3

Work Cables

For Stick/TIG welding Direct Current Elec-

trode Positive (DCEP), connect work

cables to Negative (−) terminals and elec-

trode holder cables to CC terminals.
For Stick/TIG Direct Current Electrode

Negative (DCEN), connect work cables to

CC terminals and electrode holder cables

to Negative (−) terminals.
If unit has the Polarity switch option, con-

nect work cables to Work receptacles and

electrode holder cables to Electrode recep-

tacles.

.

Be sure Process Selector switches are
set correctly. See Section 6-3.

Tools Needed:

Welder A (Left) Side

3/4 in

Welder B (Right) Side

1

2

3

2

Direct Current Electrode Positive

(DCEP) connections are shown.

Note position

of Process

Selector

switches.

Advertising