OM-494 Page 31

6-3. Weld Control Descriptions (See Section 6-2)

1

Welder Selector Switch

Use switch to select Dual Operator or Single

Operator welding mode.
Place switch in Welder A/Welder B (dual oper-

ator) position for CC and CV output from Weld-

er A (left) and Welder B (right) weld output ter-

minals. Control the weld output from the termi-

nals on each side using the weld controls on

that same side.
Place switch in Welder B (single operator)

position for CC weld output from Welder B

(right) weld output terminals only. CV weld out-

put terminals on both sides do not work when

unit is in Single Operator mode.

.

Welder A (left) weld output terminals are

disabled in Single Operator mode. Con-

nect only to Welder B (right) terminals for

Single Operator operation.

.

When in single Operator mode, only CC

weld output is available. Welder A (left)

and Welder B (right) side CV weld output

terminals are disabled in Single Operator

mode. (see Section 5-8).

2

Process Selector Switch

Use switch to select output for weld process.

If switch is in Stick/Tig position, place Welder

Selector switch in Welder A/Welder B or Weld-

er B Position. If switch is in MIG position, place

Welder Selector switch in Welder A/Welder B

position only.

.

CV weld output for MIG is only available
when Welder Selector switch is in Welder

A/Welder B position. All weld output

stops if either Process Selector switch

is placed in MIG position when Welder

Selector switch is in Welder B position.

.

Place optional Polarity switch in Reverse
position when using CV weld output.

There is no CV weld output when Polarity

switch is in Straight position.

Y Do not switch under load or with out-

put on.

3

Arc Force (Dig) Control

Use control to automatically increase amper-

age as arc length is decreased to assist in arc

starts and reduce the chance of the electrode

sticking in the puddle. Turn clockwise to in-

crease short-circuit amperage. Set at mini-

mum for TIG welding.

4

Hot Start Switch

Use switch to disable hot start circuit. Turn

switch On for Stick (SMAW) and Submerged

Arc (SAW) Welding, and Air Carbon Arc Cut-

ting and Gouging (CAC-A). Turn switch Off for

TIG (GTAW) welding.

When switch is in On position, higher short-cir-

cuit amperage helps arc starting. After arc

starts, the front panel or remote Amperage/

Voltage control setting determines weld am-

perage.

.

The hot start circuit does not function

when constant voltage (CV) welding.

5

Amperage/Voltage Control

When Process Selector switch is in the Stick/

TIG position, turn control clockwise to in-

crease amperage. Read amperage from outer

scale of control. The Amperage/Voltage con-

trol adjusts amperage only when constant cur-

rent (CC) welding and does not adjust open-

circuit voltage.

When Process Selector switch is in the MIG

position, turn control clockwise to increase

voltage. Voltmeter value changes as control

knob is turned. Control can be adjusted while

welding.

.

When Welder Selector switch is in Welder
B position (single operator mode), weld

amperage is two times the value selected

by the Amperage/Voltage control. For ex-

ample, if Amperage/Voltage control is set

to 250 A, weld output is actually 500A.

6

Weld Meters

With Process Selector switch in the Stick/Tig

position, meters read 0 (zero) with contactor

off. Meters display actual output voltage and

amperage with contactor on.

With Process Selector switch in the MIG posi-

tion, voltmeter displays preset voltage with

contactor off. Voltmeter and ammeter display

actual output voltage and amperage with con-

tactor on.

7

High Temperature Shutdown Light

Light goes on and weld output stops if weld

rectifier gets too warm. Let unit cool before

welding.

8

Remote Amperage/Voltage Control

Switch

For front panel control, place switch in Panel

position. For remote control, place switch in

Remote position, and connect remote device

(see Section 5-17).

9

Output (Contactor) Switch

For front panel control of output, place switch

in On (Hot) position. For remote control of out-

put, place switch in Remote position, and con-

nect remote device (see Section 5-17).

Y Weld output terminals are energized

when Output (Contactor) switch is On

and engine is running.

10 Polarity Switch (Optional)

Y Do not switch under load.

Use switch to change polarity of weld output

(see Sections 5-7 thru 5-14).

.

Place optional Polarity switch in Reverse
position when using CV weld receptacle.

There is no CV weld output when switch is

in Straight position.