8. resetting fan belt safety shutdown – Miller Electric Miller DU-OP User Manual

Page 43

Advertising
background image

OM-494 Page 39

8-8. Resetting Fan Belt Safety Shutdown

158 715 / Ref. 158 632 / Ref. 190 377

Y Stop engine.
1

Cooling Fan V-Belt

See engine manual to replace or

tighten belt.
If belt breaks or becomes loose,

safety shutdown stops engine.
Correct problem, then reset safety

shutdown as follows:
2

Rod

3

Stop

4

Bracket

5

Handle

Pull handle towards front of unit un-

til stop snaps in position behind

bracket.
Close door.

1

3/8 in

Right Side

5

2

3

4

Tools Needed:

Pull Handle To

Reset Shutdown

Advertising