5. adjusting engine speed, 6. servicing optional ether starting aid – Miller Electric Miller DU-OP User Manual

Page 41

Advertising
background image

OM-494 Page 37

8-5. Adjusting Engine Speed

Ref. 045 768-B

Engine speed is factory set and

should not require adjustment. Af-

ter tuning engine, check engine

speed with tachometer. See table

for proper no load speed. If neces-

sary, adjust speed as follows:
1

High Speed Stop Screw

2

Lock Nut

Loosen nut. Turn screw out (toward

front of engine) several turns.
3

Linkage

4

Lock Nuts

Loosen nuts. Start engine and

move linkage until engine runs at

weld/power speed. Tighten nuts.
Y Stop engine.
5

Speed Control Lever

Turn screw in until screw touches

lever. Tighten lock nut on screw.
Close side door.

3/8 in

1

3

2

4

Right Side

5

RPM (HZ)

1850 (61.6)

Tools Needed:

Engine Speed

(No Load)

Weld/Power

8-6. Servicing Optional Ether Starting Aid

ether2 7/96 − 153 382-A / Ref. 190 377 / S-0692

Y Stop engine.
Y Improper handling or expo-

sure to ether can harm your

health. Follow manufactur-

er’s safety instructions on

cylinder.

If engine does not start in cold

weather, check ether cylinder as

follows:
Remove cylinder from valve.
1

Ether Cylinder

2

Valve

3

Scale

Weigh cylinder to see if it is empty.
Be sure atomizer is not plugged and

valve fitting is clean.
Replace cylinder according to

Section 5-16.

1

2

15 oz

33 oz

(935 g)

(425 g)

3

Full

Empty

Advertising