Miller Electric Miller DU-OP User Manual

Page 27

Advertising
background image

OM-494 Page 23

5-13. Making Dual Operator CC And CV Weld Connections w/ Common Work Cable

Ref. 190 377 / 802 292-A

Y Stop engine.
Y Do not exceed machine duty cycle.

.

For common work connection, work
cable must be able to carry combined

weld output of both CC weld output ter-

minals (see Section 5-15 for proper

cable size).

.

Use Dual Operator mode for CC and CV
welding (see Section 6-1).

1

Strain Reliefs

Route cables through strain reliefs.
2

Electrode Holder Cable

3

Wire Feeder Cable

4

Work Jumper Cable

5

Common Work Cable

For Direct Current Electrode Positive

(DCEP), connect common work cable and

work jumper cable to Welder B (right) Nega-

tive (−) terminal. Connect other end of work

jumper cable to Welder A (left) Negative (−)

terminal.

Connect electrode holder cable to either CC

terminal.

Connect wire feeder cable to CV terminal on

other side.

.

Be sure Process Selector switches are
set correctly. See Section 6-3
.

For Direct Current Electrode Negative

(DCEN), connect common work cable and

work jumper cable to Welder B (right) CC

terminal. Connect other end of work jumper

cable to Welder A (left) CV terminal.

Connect electrode holder cable to either

Negative (−) terminal, and wire feeder cable

to remaining Negative (−) terminal.
If unit has the Polarity switch option, connect

common work cable and work jumper cable

to Welder B (right) Work receptacle. Con-

nect other end of work jumper cable to Weld-

er A (left) Work receptacle.
Connect electrode holder cable to either

Electrode receptacle.
Connect wire feeder cable to CV receptacle

on other side.

.

Place optional Polarity switch in Re-
verse position when using CV weld re-

ceptacle. There is no CV weld output

when switch is in Straight position.

.

Be sure Process Selector and Polarity
switches are set correctly. See Section

6-3.

Tools Needed:

Welder A (Left) Side

3/4 in

Welder B (Right) Side

Y INADEQUATE CABLE CONNECTIONS can cause serious damage to welding generator and create a hazardous condition.

When making weld connections with a common work cable, connect a weld cable of adequate size between the Negative (−) weld termi-

nals, and connect a single weld cable of adequate size from the Welder B (right) Negative (−) terminal to the workpiece.
When using these connections as a common work terminal, all connections must be of the same polarity.
For a common work cable connection, the work cable must be able to carry the combined weld output of both modules (see Section 5-15

for proper cable size).

1

2

3

4

5

Direct Current Electrode Positive

(DCEP) connections are shown.

Note position

of Process

Selector

switches.

Note position of

optional Polarity

switch.

Advertising