OM-494 Page 20

5-10. Making Dual Operator CV Weld Connections w/ Separate Work Cables

Ref. 190 377 / 802 292-A

Y Stop engine.
Y Do not exceed machine duty cycle.

.

Use Dual Operator mode for CC and
CV welding (see Section 6-1
).

See Section 5-15 for proper cable size.
1

Strain Reliefs

Route cables through strain reliefs.
2

Wire Feeder Cables

3

Work Cables

For MIG and FCAW welding Direct Current

Electrode Positive (DCEP), connect work

cables to Negative (−) terminals and wire

feeder cables to CV terminals.

For MIG and FCAW Direct Current Elec-

trode Negative (DCEN), connect work

cables to CV terminals and wire feeder

cables to Negative (−) terminals.

If unit has the Polarity switch option, con-

nect work cables to Work receptacles and

wire feeder cables to CV receptacles.

.

Place optional Polarity switches in Re-
verse position when using CV weld re-

ceptacles. There is no CV weld output

when switch is in Straight position.

.

Be sure Process Selector and Polarity

switches are set correctly. See Section

6-3.

Tools Needed:

Welder A (Left) Side

3/4 in

Welder B (Right) Side

1

2

3

2

Direct Current Electrode Positive

(DCEP) connections are shown.

Note position

of Process

Selector

switches.

Note position

of optional

Polarity

switch.

Note position

of optional Po-

larity switch.