OM-1594 Page 25

5-15. Setting Switches For Preflow And Postflow

.

Unit arrives from the factory
with preflow Off and postflow

turned On.

To set switches for preflow and

postflow, proceed as follows:
1

Motor Speed Control Board

PC1

2

DIP Switch S1

.

Preflow and postflow have pre-
set time values and cannot be

changed.

To provide a 3.5 second preflow

time, use a small nonconductive

screwdriver to set switch S1-1 in

the up position. To turn preflow time

off, set S1-1 in the down position.
To provide a 0.5 second postflow

time, use a small nonconductive

screwdriver to set switch S1-2 in

the up position. To turn postflow

time off, set S1-2 in the down

position.
Reinstall side panel.

Ref. 801 557-B / 197 716

1

2

Top Of PC1

Tools Needed:

Nonconductive

1/4 in

Advertising