OM-1594 Page 26

5-16. Adjusting Trigger Hold Actuation Time

To adjust trigger hold actuation

time, proceed as follows:
1

Motor Speed Control Board

PC1

2

Potentiometer R50

.

Trigger hold actuation time
range is from 0 to 4 seconds.

To decrease trigger hold actuation

time, use a small nonconductive

screwdriver and rotate

potentiometer clockwise; to

increase actuation time, rotate

potentiometer counterclockwise.
Reinstall side panel.

Tools Needed:

Nonconductive

1/4 in

Ref. 801 557-B / 197 716

1

2

Top Of PC1