5-16. Adjusting Trigger Hold Actuation Time
To adjust trigger hold actuation
time, proceed as follows:
1
Motor Speed Control Board
PC1
2
Potentiometer R50
.
Trigger hold actuation time
range is from 0 to 4 seconds.
To decrease trigger hold actuation
time, use a small nonconductive
screwdriver and rotate
potentiometer clockwise; to
increase actuation time, rotate
potentiometer counterclockwise.
Reinstall side panel.