SECTION 3- SPECIFICATIONS

Table 3-1. Specifications

Input Power

Requirements

Electrode Wire

Diameter Capacity

Wire Spool

Capacity

Electrode Wire

Feed Speed

Weight

Net

Ship

10 to 20 lb.

24 VAC

3.5 Amps

50/60 Hz

.O23thru .045 in.

(0.6 thru 1.1 mm)

(4.5 to 9 kg)

8 in. (203mm) spools

up to 60 lb.

(27.2 kg)_coils

75-600 ipm

(1.9-15.2 mom)

at 24 VA~

30 lbs.

(13.6 kg)

33 lbs.

(15 kg)

SB-124 467

Figure 3-1. Overall Dimensions

3-1.

DESCRIPTION

This unit is a semiautomatic constant speed wire feeder
which operates on 24 volts ac. The feeder is designed
for connection to a constant voltage (CV) type power
source through a 14-pin connector. If 115 volts ac is the

only power available for use with the feeder, the optional

power supply adapter Model PSA-2 115/24 should be
used to convert the power to 24 volts ac.

The case can be tightly latched to help keep out dust and
dirt.

SECTION 4- INSTALLATION OR RELOCATION

4-1.

LOCATION (Figure 3-1)

The service life and efficiency of this unit and associated
components are reduced when they are subjected to
high levels of dust, dirt, moisture, corrosive vapors, and
extreme heat.
A proper installation site should be selected for the wire
feeder if the unit is to provide dependable service. Lead

lengths must be considered when installing the unit. A

slot is provided in the base of the unit to fit over the lifting
eye on welding power sources so equipped. Suitable
space should be maintained around the unit for making

necessary connections and for maintenance functions.

4-2.

DRIVE ROLL INSTALLATION (Figure 4-1)

A

WARNING: ELECTRIC SHOCK can kill.

• Do not touch live electricalparts.
• Shut down wire feeder and welding power

source, and disconnect input power employ-

ing lockout/tagging procedures before in-

specting or installing.

Lockout/tagging procedures for wire feedercon-

sist of disconnecting interconnecting cord, and

for welding power source consist of padlocking

line disconnect switch in open position, remov-

ing fuses from fuse box, or shutting off and red-

tagging circuit breaker or other disconnecting

device. Stop engine, and disconnect negative

(—)

battery cable from battery on welding gen-

erators.

TM-1571 Page 3

10-112 In.

(267 mm)

22-1(2 in.

(572 mm)

S-21E