4-20. TIG Lift-Arc Welding

1

1 − 2

Seconds

“Touch”

Do NOT Strike Like A Match!

2

Ref. S-156 279

Lift-Arc Start
When Lift-Arct button light is On,

start arc as follows:
1

TIG Electrode

2

Workpiece

Touch tungsten electrode to work-

piece at weld start point, enable out-

put and shielding gas with torch trig-

ger, foot control, or hand control.

Hold electrode to workpiece for

1-2 seconds, and slowly lift elec-

trode. Arc is formed when electrode

is lifted.
Normal open-circuit voltage is not

present before tungsten electrode

touches workpiece; only a low

sensing voltage is present between

electrode and workpiece. The

solid-state output contactor does

not energize until after electrode is

touching workpiece. This allows

electrode to touch workpiece with-

out overheating, sticking, or getting

contaminated.
Application:
Lift-Arc is used for the DCEN or AC

GTAW process when HF Start

method is not permitted, or to re-

place the scratch method.

4-21. Preparing Unit For Stick Welding

To select STICK welding process, proceed

as follows:
Follow safety precautions according to

Section 1.
Prepare unit according Section 3.
Using a cable with a proper adapter, con-

nect electrode holder to the MIG gun con-

nector.

Connect work clamp cable to the WORK

connector.

If a remote control is desired, connect it to

the Remote Control receptacle.

Turn unit On.

Allow time for unit to complete its start up

cycle.

Set STICK welding process using P3 push

button.

.

Be aware that STICK welding can be
enabled (L16 On) or disabled (L16 Off)

using P6 push button, and this status

is retained in the STICK welding pro-

cess memory.

4-22. Stick Welding Advanced Settings

HOT START

To change HOT START setting, proceed

as follows:

Press P2 to enter SET UP menu.

Select MENU FULL on D1 and D2 (see

Section 4-10).

Use E1 to change D1 to HOT.

D2 value is default setting of 100% (range

is 0% to 100%).
Use E2 to change D2 value.
This parameter increases output amper-

age at the start of a weld to eliminate elec-

trode sticking.
ARC FORCE
To change ARC FORCE setting, proceed

as follows:
Press P2 to enter SET UP menu.

Select MENU FULL on D1 and D2 (see

Section 4-10).

Use E1 to change D1 to ARC.

D2 value is default setting of 80% (range is

0% to 100%).

Use E2 to change D2 value.

When setting is increased, short-circuit

amperage at low arc voltage increases.