3-14. Selecting Input Voltage (200/230/460 Volt Models Only)

803 539-B / 804 042-A

!

Turn Off welding power
source, disconnect input
power, and check voltage on
input capacitors according
to Section 6-3
before
proceeding.

.

Check input voltage available
at site.

.

Incorrect linking can damage
unit and void the warranty.

1

Voltage Selection View
Window

Check voltage selected in unit.
Changing selection is only neces-
sary if selected value does not
match available input voltage.

2

Relinking Board PC6

3

Mounting Screws

4

Receptacle RC23
(Connection For 230 VAC
Input Power)

5

Receptacle RC46
(Connection For 460 VAC
Input Power)

Move relinking board as needed
and connect plug PLG32 (in unit) to
RC23 or RC46 according to input
power voltage.

1

Tools Needed:

5/16 in

.

Be sure to reinstall all four screws
securing relinking board in place.

2

3

4

3

5

Advertising