Miller Electric Millermatic 350 User Manual

Page 37

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-1327 Page 33

5-4.

Arc Times, Arc Starts, Hot Start (Aluminum Pulse Only), And Crater Fill

Arc times and number of arc starts are
saved in unit memory. To view this
information, press both SETUP (1) and
ARC CONTROL (2) buttons at the same
time.

Left display will initially show arc hours.

Rotate left knob (3) and display will change
to show number of arc starts.

To turn on the Crater Fill display, rotate left
knob (3) until

CRTR

appears in the left

display. The factory default for Crater Fill
display is

OFF

which appears in the right

display. Rotate the right knob (4) until

ON

appears in the display.

.

The Crater Fill display can be turned
off after parameters are set in pro-
grams, but remember that once crater
fill is turned on in any program, it will
remain on even though it does not ap-
pear in the displays because Crater
Fill display is turned off.

To exit this menu, press either the SETUP
(1) or ARC CONTROL (2) button, or press
a gun trigger on any welding gun
connected to the unit.

Ref. 213 935-A

4

1

2

.

Accessing the Arc Times, Arc Starts, Hot Start (aluminum pulse only), and
Crater Fill data will also allow access to Software Version data and Motor
Calibration function. The software version data and motor calibration func-
tion are for use by factory authorized service personnel only.
Do not use the motor calibration function if it appears on the displays.

3

Advertising