Warning, 1. routine maintenance, 6 months – Miller Electric XMT 4-Rack User Manual

Page 15: 3 months

Advertising
background image

Ref. S-0092-G

OM-815 Page 11

Table 4-2. Electrical Service Requirements*

Input Voltage

230

460

Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

1

250

125

Input Conductor Size In AWG/Kcmil

2

1/0

4

Max Input Conductor Length

In Feet (Meters)

3

229 (70)

397 (121)

Grounding Conductor Size In AWG/Kcmil

4

4

6

*

These values are calculated from the 1993 edition of the National Electrical Code (NEC).

1 Recommended fuse or circuit breaker size is that closest to 150% of rated input amperage of the welding power source. Article 630-12(a) of NEC

allows fuse or circuit breaker sizing up to 200% of rated input amperage.

2 Input conductor size is for insulated copper wire with 75

°

C rating with not more than three single current-carrying conductors in a cable or raceway

(Table 310-16 of NEC).

3 Maximum length is to prevent more than a 3% voltage drop between service entrance and input terminals of the welding power source (Articles

210-19(a) and 215-2(b) of NEC).

4 The grounding conductor shall be colored or identified as specified in the NEC. Grounding conductor size for copper wire is not required to be larger

than input conductor (Article 250-95 of NEC).

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

ELECTRIC SHOCK can kill.

•

Do not touch live electrical parts.

•

Turn Off welding power sources, and disconnect input power to rack before inspecting, maintaining, or servicing.

Maintenance to be performed only by qualified persons.

WARNING

5-1.

Routine Maintenance

Turn Off all power before maintaining.

ST-151 267-B

6 Months

OR

During Heavy Service,

Clean Monthly

Blow Out

Or

Vacuum

Inside

– –

3 Months

Tape Or

Replace
Cracked

Cables

Clean

And

Tighten Weld

Connections

Replace

Unreadable

Labels

See

Section

7

Figure 5-1. Maintenance Schedule