Table 4-2. Electrical Service Requirements*

Input Voltage

230

460

Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

1

250

125

Input Conductor Size In AWG/Kcmil

2

1/0

4

Max Input Conductor Length

In Feet (Meters)

3

229 (70)

397 (121)

Grounding Conductor Size In AWG/Kcmil

4

4

6

*

These values are calculated from the 1993 edition of the National Electrical Code (NEC).

1 Recommended fuse or circuit breaker size is that closest to 150% of rated input amperage of the welding power source. Article 630-12(a) of NEC

allows fuse or circuit breaker sizing up to 200% of rated input amperage.

2 Input conductor size is for insulated copper wire with 75

°

C rating with not more than three single current-carrying conductors in a cable or raceway

(Table 310-16 of NEC).

3 Maximum length is to prevent more than a 3% voltage drop between service entrance and input terminals of the welding power source (Articles

210-19(a) and 215-2(b) of NEC).

4 The grounding conductor shall be colored or identified as specified in the NEC. Grounding conductor size for copper wire is not required to be larger

than input conductor (Article 250-95 of NEC).

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Turn Off welding power sources, and disconnect input power to rack before inspecting, maintaining, or servicing.

Maintenance to be performed only by qualified persons.

WARNING

5-1.

Routine Maintenance

Turn Off all power before maintaining.

ST-151 267-B

6 Months

OR

During Heavy Service,

Clean Monthly

Blow Out

Or

Vacuum

Inside

– –

3 Months

Tape Or

Replace
Cracked

Cables

Clean

And

Tighten Weld

Connections

Replace

Unreadable

Labels

See

Section

7

Figure 5-1. Maintenance Schedule