OM-815 Page 12

5-2.

Overload Protection

1

Power Circuit Breakers
CB1-CB4

Each Power circuit breaker CB1
through CB4 protects the welding
power source connected to it from
overload.

If a Power circuit breaker opens,
the matching welding power source
would shut down. Manually reset
the Power circuit breaker.

ST-158 333 / Ref. ST-155 839 / Ref. ST-151 269-B

1

Figure 5-2. Circuit Breaker Locations

5-3.

Troubleshooting

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Turn Off welding power sources, and disconnect input power to rack before inspecting, maintaining, or servicing.

Troubleshooting to be performed only by qualified persons.

WARNING

Table 5-1. Rack Trouble

Trouble

Remedy

Section

No weld output from any welding power
sources; units completely inoperative.

Place line disconnect switch in On position.

4-6

Check line fuse(s) and replace if needed. Reset circuit breakers.

4-6

Check for proper input power connections to rack.

4-6

No weld output from one welding power
source.

Place applicable Power circuit breaker in On position.

5-2

Check for proper input power connections to welding power source.

4-3

Check applicable welding power source according to its manual.

– –