OM-815 Page 12

5-2.

Overload Protection

1

Power Circuit Breakers
CB1-CB4

Each Power circuit breaker CB1
through CB4 protects the welding
power source connected to it from
overload.

If a Power circuit breaker opens,
the matching welding power source
would shut down. Manually reset
the Power circuit breaker.

ST-158 333 / Ref. ST-155 839 / Ref. ST-151 269-B

1

Figure 5-2. Circuit Breaker Locations

5-3.

Troubleshooting

ELECTRIC SHOCK can kill.

•

Do not touch live electrical parts.

•

Turn Off welding power sources, and disconnect input power to rack before inspecting, maintaining, or servicing.

Troubleshooting to be performed only by qualified persons.

WARNING

Table 5-1. Rack Trouble

Trouble

Remedy

Section

No weld output from any welding power
sources; units completely inoperative.

Place line disconnect switch in On position.

4-6

Check line fuse(s) and replace if needed. Reset circuit breakers.

4-6

Check for proper input power connections to rack.

4-6

No weld output from one welding power
source.

Place applicable Power circuit breaker in On position.

5-2

Check for proper input power connections to welding power source.

4-3

Check applicable welding power source according to its manual.

– –