TM-499 Page 8

SECTION 4 − INSTALLATION

4-1. Installing Welding Generator

install1 10/00*− 802 524-A / Ref. 151 556 / 158 936-A / S-0854

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Y Always securely fasten welding

generator onto transport vehicle

or trailer and comply with all DOT

and other applicable codes.

4-2. Grounding Generator To Truck Or Trailer Frame

install1 10/00* − Ref. 151 556 / S-0854

Y Always ground generator

frame to vehicle frame to pre-

vent electric shock and static

electricity hazards.

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding

Terminal

4

Grounding Cable

Use #10 AWG or larger insulated

copper wire.
Y If unit does not have GFCI re-

ceptacles, use GFCI-

protected extension cord.

1

2

Electrically bond generator frame to
vehicle frame by metal-to-metal con-
tact.

GND/PE

3

4

2

OR