background image

TM-499 Page 38

10-3. Test Points And Values (Use With Section 10-2)

Voltage Readings

a) Tolerance −

±

10% unless specified

b) Condition − 70

°

F (21

°

C); cold

machine (no warm-up); no load

c) Weld/power rpm unless specified
d) Reference − single arrow: reference

to circuit common (lead 11); double

arrow: reference to points indicated

e) Wiring Diagram − see Section 12

V1

122 volts ac

±

5% (60 Hz)

110 volts ac

±

5% (50 Hz)

V2

122 volts ac

±

5% (60 Hz)

110 volts ac

±

5% (50 Hz)

V3

76 volts ac (60 Hz)

69 volts ac (50 Hz)

V4

50 volts dc (60 Hz)

70 volts dc (50 Hz)

V5

At 25 volt, 100 ampere weld load:

Less than 1 volt dc (60 and 50 Hz)

V6

68 volts dc (60 Hz)

62 volts dc (50 Hz)

V7

0 − 10 volts dc (60 or 50 Hz)

V8

15 volts dc (60 or 50 Hz)

V9

23.5 volts ac (60 Hz)

20.5 volts ac (50 Hz)

V10

200 volts dc (60 Hz)

176 volts dc (50 Hz)

V11

18.2 volts ac (60 Hz) − Kohler Only

15.5 volts ac (50 Hz) − Kohler Only

Resistance Values

a) Tolerance −

±

10% unless specified

b) Condition − 70

°

F (21

°

C); cold

machine (no warm-up)

c) Wiring Diagram − see Section 12
d) Stop engine before checking

resistance

R1

27 ohms

R2

20 ohms (Kohler Only)

R3 thru R8

Less than 1 ohm

Amperage Readings

a) Tolerance −

±

5% unless specified

b) Condition − 70

°

F (21

°

C); cold

machine (no warm-up); no load

I1

1.8 amps dc (60 Hz)

2.3 amps dc (50 Hz)

Test Equipment Needed:

Advertising