TM-499 Page 20

7-3. Overload Protection (Honda-Powered Units)

1

Ignition Circuit Breaker

(Electric-Start Models Only)

The circuit breaker protects the en-

gine battery charging circuit. A

short circuit or a battery connected

in reverse polarity will trip the circuit

breaker.
Press button to reset breaker.

.

If breaker continues to open,
check starter solenoid (see en-
gine manual).

1

Ref. 802 094-A

3

1

2

7-4. Adjusting Engine Speed (Kohler-Powered Units)

802 511-A / Kohler Dwg.

After tuning engine, check engine

speeds. See table for proper no

load speeds. If necessary, adjust

speeds as follows:
Start engine and run until warm.
Weld/Power Speed

Adjustment
1

Throttle Control Lever

2

Adjustment Screw

Move lever to Run (far right) posi-

tion. To increase speed, turn screw

out (counterclockwise) while lightly

pushing lever to the right. To de-

crease speed, turn screw in (clock-

wise).
Idle Speed Adjustment
3

Adjustment Screw

Move lever to idle (far left) position.

To increase idle speed, turn screw

in (clockwise). To decrease idle

speed, turn screw out (counter-

clockwise).
Y Stop engine. Close fuel

valve.

Tools Needed:

2000

±

150 rpm

3720

±

50 rpm (60 Hz)

3250

±

50 rpm (50 Hz)

Top View

Top View