Miller Electric BLUE STAR 6000 TM-499C User Manual

Page 32

Advertising
background image

TM-499 Page 28

PART NAME

CIRCUIT SYMBOL

PICTURE

FUNCTION

SCR

A Silicon Controlled Rectifier (SCR) is an

electrical device with three connections,

anode, cathode, and gate. It will allow current

to flow in only one direction and will only do

so after receiving a signal on the gate lead.

SCR’s are used to change AC to DC and to

control the output to a load such as a welding

arc.

K

A

G

SHUNT

A precision low-value resistor typically used

to supply a small voltage to drive an

ammeter.

SHUNT

SNUBBER

A device used to absorb voltage spikes,

sometimes found connected across the

points of a relay.

SN1

SPARK GAP

The arrangement of two electrodes between

which a discharge of electricity will occur.

Typically used to produce “ high frequency”

which can be used for arc starting when TIG

welding.

G

STABILIZER/

REACTOR

When placed in a DC circuit, the inductor or

stabilizer as it is usually called, will oppose

any change in existing current. It is therefore

widely used to “stabilize” the welding arc.

When the inductor is placed in an AC circuit it

is referred to as a reactor where it now acts

to restrict the flow of current. A “tapped

reactor” is used to create current ranges for

welding.

Z1

L1

SWITCH

A mechanical device that completes or

breaks the path of the current or sends it over

a different path.

SPDT

SPST

A multi-pole switch will use dashed lines to

connect poles.

SPST = Single Pole Single Throw

SPDT = Single Pole Double Throw

DPST = Double Pole Single Throw

DPDT = Double Pole Double Throw

DPDT

DPST

MOMENTARY

SWITCH

A switch that “springs back” to its original

position.

S1

LIMIT SWITCH

A switch mounted in the path of a moving

object and actuated by its passage.

NRM OPEN

NRM

CLOSED

S1

S1

PUSH BUTTON

SWITCH

A switch in which a button must be

depressed each time the contacts are to be

opened or closed.

NRM

OPEN

NRM

CLOSED

PB1

PB1

ROTARY SWITCH

A switch in which its shaft must be rotated to

actuate the contacts.

S1

S1

Advertising