EXAMPLE #3:

The following example shows the events that occur when an invalid bar code
is sent. This sample will load the factory default settings and then set the
baud rate to 19200.


FEATURE


HOST COMMAND

ASCII REPRESENTATION

RESPONSE

SCANNER
RESPONSE

Enter Configuration Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

Load Defaults

[stx]99999:[etx]

02h 39h 39h 39h 39h 39h 3Ah 03h

[ack] or 06h

Invalid command was sent, you must start over!

Enter Configuration Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

Load Defaults

[stx]999998[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

19200 Baud Rate

[stx]415870[etx]

02h 34h 31h 35h 38h 37h 30h 03h

[ack] or 06h

Exit Configuration Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

The scanner will beep three times!

This example illustrates two important points.

First, if an invalid command is sent from the host, the scanner responds with
a [nak] and the end-user must start over from the beginning.

Second, if a command is sent to change the Baud Rate, the new baud rate
does not take effect until after the end-user exits configuration mode.

ABBREVIATED ASCII TABLE

Character

Hex Value

Decimal Value

[STX] 02h 2
[ETX] 03h 3

[ACK] 06h 6
[NAK] 15h 21

0 30h 48
1 31h 49
2 32h 50
3 33h 51
4 34h 52
5 35h 53
6 36h 54
7 37h 55
8 38h 56
9 39h 57