background image

34

D

ESIGN

S

PECIFICATIONS

D

ESIGN

S

PECIFICATIONS

E

LECTRICAL

Input Voltage: 5.0VDC ± 0.25V

Power:

Operating = 900 mW (typical)

Standby = 325 mW (typical)

Current:

Operating = 250 mA @ 5VDC (typical)

Standby

=

100 mA @ 5VDC

(typical)

DC Transformers: Class 2; 5.2VDC @ 650 mA

Laser Class 1:

IEC 60825-1:1993+A1:1997+A2:2001

EN 60825-1:1994+A11:1996+A2:2001

EMC:

FCC, ICES-003 & EN55022 Class B
Refer to page 45 for Class B cable restrictions.

E

NVIRONMENTAL

Temperature:

Operating = 0°C to 40° (32° to 104°F)

Storage = -40°C to 60°C (-40°F to 140°F)

Humidity: 5% to 95% relative humidity, non-condensing

Light Levels:

Immune to direct exposure of normal office and factory
lighting conditions, as well as direct exposure to sunlight.

Shock: Designed to withstand 1.5 m (5’) drops

Contaminants: Sealed to resist airborne particulate contaminants

Ventilation: None

required

Specifications subject to change without notice.