OM-129 647 Page 25

6-2. Optional Auxiliary Power Receptacles

Ref. ST-180 933-B / Ref. ST-182 266

.

Auxiliary power is not affected
by weld output.

If a circuit breaker continues to

open, contact Factory Autho-

rized Service Agent.

GFCI Receptacle Option
1

120 V 15 A AC GFCI

Receptacle GFCI1

Auxiliary power output and circuit

breaker protection is the same as

standard receptacles (see Section

6-1).
If a ground fault is detected, GFCI

Reset button pops out and

receptacle does not work. Check

for faulty tools plugged in

receptacle. Press button to reset.

.

At least once a month, run en-
gine at weld/power speed and

press test button to verify

GFCI is working properly.

Australian And South African

Receptacle Options
2

240 V 10 A AC Australian

Receptacle RC1

3

240 Volt 13 A AC South

African Receptacle RC1

RC1 supplies 60 Hz single-phase

power at weld/power speed. Maxi-

mum output from receptacle is 3

kVA/kW.
4

Circuit Breaker CB1

CB1 protects RC1 from overload. If

CB1 opens, RC1 does not work.

Press button to reset breaker.
British Receptacle Option
5

240 Volt 13 A AC British

Receptacles RC1 And RC2

RC1 and RC2 supply 60 Hz single-

phase power at weld/power speed.

Maximum combined output from

both receptacles is 3 kVA/kW.
6

Circuit Breaker CB1

CB1 protects RC1 and RC2 from

overload. If CB1 opens, the recep-

tacles do not work. Press button to

reset breaker.

2

4

5

1

4

3

6