6-3. Connecting Optional Auxiliary Power Plant

Ref. S-180 187-A

Y Stop engine.
Y Power and weld outputs are

live at the same time. Discon-

nect or insulate unused

cables.

Have qualified person install

according to circuit diagram and

Auxiliary Power Guidelines Booklet

(M176 712).
Remove junction box cover.
1

Lead 93

2

Lead 92

3

Lead 91

4

Lead 90 (Neutral)

5

Lead 42 (Circuit Grounding

Lead)

Lead 42 connects to front panel

Ground stud.
6

Grounding Terminal

7

Jumper Lead 42

8

Isolated Neutral Terminal

Jumper 42 is connected to lead 90

at factory. Jumper 42 may be dis-

connected from neutral to meet

applicable electrical codes.
9

User-Supplied Leads

10 Load Terminals
Connect leads to terminals.
11 Fuses F1, F2, And F3
F1, F2, and F3 protect each load

line from overload.

.

Set Engine Control switch to
Run when using auxiliary

power.

4

5

7

8

9

6

10

11

Tools Needed:

93

91

90

92

240V

120V

120V

240V

240V

240V

1

3

Volts

Amps

KVA/KW

Single

120/240

31

7.5

Three

240

24

10

60 Hz

Frequency

Engine Speed

Max. Fuse Size

35 Amperes

1850 RPM

AC

Phase

1

Phase

3

Output

Lead 42 connects to GROUND stud on front of

unit.

Jumper 42 is connected to 90 at factory.

F3

F2

F1

1

2

3

7

8