7-5. Adjusting Engine Speed

ST-045 768-B

Engine speed is factory set and

should not require adjustment. Af-

ter tuning engine, check engine

speed with tachometer. See table

for proper no load speed. If neces-

sary, adjust speed as follows:
1

Plastic Cap

2

High Speed Stop Screw

3

Lock Nut

Remove plastic cap from screw.

Loosen nut. Turn screw out (to-

ward front of engine) several turns.
4

Linkage

5

Lock Nuts

Loosen nuts. Start engine and

move linkage until engine runs at

weld/power speed. Tighten nuts.
Y Stop engine.
6

Speed Control Lever

Turn screw in until screw touches

lever. Tighten lock nut on screw

and reinstall plastic cap.
Close side door.

1

3/8 in

2

4

3

5

Right Side

6

RPM

1850

Tools Needed:

Engine Speed

(No Load)

Weld/Power

7-6. Servicing Optional Ether Starting Aid

ether2 7/96 − ST-153 382-A / Ref. ST-180 933-B / S-0692

Y Stop engine.
Y Improper handling or expo-

sure to ether can harm your

health. Follow manufactur-

er’s safety instructions on

cylinder.

If engine does not start in cold

weather, check ether cylinder as

follows:
Remove cylinder from valve.
1

Ether Cylinder

2

Valve

3

Scale

Weigh cylinder to see if it is empty.
Be sure atomizer is not plugged

and valve fitting is clean.
Replace cylinder according to

Section 4-8.

1

2

15 oz

33 oz

(935 g)

(425 g)

3

Full

Empty