SECTION 4 − OPERATION

4-1. Controls For Millermatic 140/180 Models

A. Spool Gun Operation On Millermatic 140/180 Models

sb5.1* 6/92 − S-0621-C / Ref. 802 982-A / 804 986-A

.

Spool Gun/MIG Gun switch on
Millermatic 140/180 must be in

Spool Gun position for spool

gun to operate.

1

Shielding Gas Cylinder

For shielding gas connections, see

welding power source Owner’s

Manual.
2

Valve

Open valve on cylinder just before

welding.
Close valve on cylinder when

finished welding.
3

Spool Gun/MIG Gun Switch

Switch must be set in Spool Gun

position for spool gun to operate.
4

Trigger

Press trigger to energize welding

power source contactor, start

shielding gas flow, and begin wire

feed.
5

Wire Feed Speed Control

Wire feed speed is controlled by

welding power source Wire Speed

control (see welding power source

Owner’s Manual or door chart for

appropriate setting).
6

Voltage Control

Arc voltage is controlled by welding

power source Voltage control (see

welding power source Owner’s

Manual or door chart for

appropriate setting).

.

To purge shielding gas line, set
gun selection switch (item 3)
to

the MIG Gun position. Press

spool gun trigger to energize

gas valve. Shielding gas will

flow, but spool gun will not feed

wire. Hold trigger in for several

seconds to purge gas line.

Return gun selection switch to

the Spool Gun position before

welding.

1

2

3

4

5

6