OM-234 016 Page 34

S

Maintain a 3/4 in. (19 mm) tip-to-work distance, and have the contact tip recessed approximately 1/8 in. inside the

nozzle if possible. See Figure 5-2.

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЙЙЙ

ЙЙЙ

Gas Nozzle

Contact Tube Recessed 1/8

in. (3.2 mm) Inside The Nozzle

Contact Tip To Work

Distance 3/4 in. (19 mm)

Figure 5-2. Contact Tube Position And Tip-To-Work Distance

S

Avoid large weave beads on aluminum. If larger fillet welds are needed, multiple pass stringer beads will provide

better appearance and have less chance of cold lapping, melt through, and other weld defects.

S

It will be necessary to increase torch travel speed as the base material becomes heated during the welding

process.

S

The skill level of the operator, joint types, fit up, and positions, as well as the welding power supply will all have a

great influence on the weldability of the aluminum and your success.

C. Common Problems/Troubleshooting

S

Melt through caused by over heating the base material.

1.

Increase travel speed. Use sequencing to make shorter welds.

2.

Sequence welds.

3.

Use thicker material, change joint design or welding process to AC TIG.

4.

Eliminate or reduce gaps.

S

Dirty welds.

1.

Use push angle instead of drag technique.

2.

Increase voltage to get into spray transfer, if unit output is capable of this process.

3.

Use proper base metal cleaning techniques (stainless steel brush).

4.

Check for proper shielding gas and wire alloy type.

S

Wire burns back to contact tip during or at the end of the weld.

1.

Maintain a 3/4 in. (19 mm) tip-to-work distance.

2.

Check to make sure the contact tip size, drive rolls and gun liner match the wire diameter that you are using.

(Sometimes an oversized tip can be used. The ID should only be one size larger than the wire diameter.)

S

Wire “bird nests” (piles up) in front of inlet guide on gun.

1.

Check and adjust drive roll tension.

2.

Check to make sure drive rolls match wire diameter.

3.

Replace contact tip if fouled or plugged.(Sometimes an oversized tip can be used. The ID should only be one

size larger than the wire diameter.)