Section 3 − definitions, Symbols and definitions, Section 4 − installation – Miller Electric OM-230 User Manual

Page 15: Specifications, 1. symbols and definitions, 1. specifications

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-230 693 Page 11

SECTION 3 − DEFINITIONS

3-1.

Symbols And Definitions

Wire Feed

Output

X

Duty Cycle

Do Not Switch
While Welding

V

Volts

Increase

On

Off

Gas Metal Arc

Welding (GMAW)

Gun

Wire Feed Spool

Gun

Gas Input

Gas Output

Voltage Input

Press To Reset

U

0

Rated No-Load

Voltage (Average)

SECTION 4 − INSTALLATION

4-1.

Specifications

Rated Output

Max. OpenCircuit

Amps Input at Rated Output (60% Duty Cycle), 60 Hz, Single-Phase

Rated Output

Max. OpenCircuit

Voltage

200 (208) V

230 V

460 V

575 V

KVA

KW

250 A at 28 VDC,

40% Duty Cycle

200 A at 28 VDC,

60% Duty Cycle

38

48

2.3*

42

2*

21

1*

17

0.8*

9.8

0.46*

7.5

0.13*

Wire Type and Diameter

Wire Feed Speed

Dimensions

Net Weight Without Gun

Solid Steel

Stainless Steel

Flux Cored

50−700 IPM

(1.3−17.8 m/min)

H: 30 in (762 mm)

W: 19 in (483 mm)

205 lb

(93 kg)

.023 − .045 in

(0.6 − 1.2 mm)

.023 − .045 in

(0.6 − 1.2 mm)

.030 − .045 in

(0.8 − 1.2 mm)

(1.3−17.8 m/min)

W: 19 in (483 mm)

D: 40 in (1016 mm)

(93 kg)

* While idling

Operating Temperature Range − −20C to +40C

Storage Temperature Range − -30C to + 50C