Welding wire birdnesting at the welding power source drive rolls may occur if this value is set too high.

5-5.

Set Up Push Motor Torque (SUP) Or Reset (rES)

1

Voltage Control

2

Wire Speed Control

3

Voltmeter

4

Wire Feed Speed Meter

Depress the gun trigger while turning on
the power switch until the left meter
displays (

run

).

Rotate the left knob counterclockwise
(CCW) to find the particular item, and rotate
the right knob to change the setting.

The following items can be adjusted by
rotating the left knob counterclockwise
(CCW):
Set up Push Motor Torque (SUP) − This
feature is only active when a push/pull gun
is connected to the welding power source.
The (SUP) setting will adjust the
over-torque limit of the push motor inside
the welding power source. The range is
0-250 and the default value is 130.
Increasing this setting will increase the

over-torque limit and speed up the remote
wire feed speed motor.

.

If Aluma-Pro push/pull gun has a listed
SUP value, set the power source to
match the SUP value.

To save settings and exit the (SUP) menu,
depress the gun trigger.
Reset (rES) − Rotate the right knob to
select ON. Press and release gun trigger to
reset system to factory default values.