5. fuel consumption, 6. duty cycle and overheating – Miller Electric Big Blue 500 PT User Manual

Page 22

Advertising
background image

OM-4429 Page 18

4-5. Fuel Consumption

The curve shows typical fuel use

under weld or power loads.

215 082−A

IDLE

DC WELD AMPERES AT 100% DUTY CYCLE

U.S. GAL./HR.

0

0.25

0.50

0.75

1.00

1.25

1.50

1.75

2.00

2.25

2.50

0

50 100 150 200 250 300 350 400 450 500 550 600

Continuous Welding

4-6. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
NOTICE − Exceeding duty cycle

can damage unit and void warranty.

100% Duty Cycle At 400 Amperes

202 356

Advertising