5. checking generator brushes, Section 9-4 – Miller Electric Big Blue 500 PT User Manual

Page 48

Advertising
background image

OM-4429 Page 44

9-4. Inspecting And Cleaning Optional Spark Arrestor Muffler

803 656 / Ref. 215 158

!

Stop engine and let cool.

1

Spark Arrestor Muffler

2

Cleanout Plug

Remove plug and remove any dirt

covering cleanout hole.
Start engine and run at idle speed to

blow out cleanout hole. If nothing

blows out of hole, briefly cover end

of exhaust pipe with fireproof

material.

!

Stop engine and let cool.

Reinstall cleanout plug.

Tools Needed:

3/8 in

1

2

9-5. Checking Generator Brushes

Ref. 215 664

!

Stop engine and let cool.

1

Generator Brush

Remove brushes from brush holder.
Replace brushes if damaged or if brush

material is at or near minimum length.

1

Damaged Brushes

New Length: 1-1/4 in (32 mm)

Minimum Length:

5/8 in (16 mm)

Replace

Advertising