And 7-4 – Miller Electric Big Blue 500 PT User Manual

Page 41

Advertising
background image

OM-4429 Page 37

7-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)

1

Remote 14 Receptacle RC14

Connect optional remote control to

RC14 (see Section 5-11).

0774 / Ref. 215 664 / Ref. 803 602

Example: Combination Remote Amperage Control (Stick)

Adjust Optional Remote Control

Set V/A

Adjust Switch

Set Range

Control Not

Used In Remote

Stick Mode

Set Remote

Process

Example: Combination Remote Amperage Control (TIG)

Adjust Optional Remote Control

Set V/A

Adjust Switch

Set Range

Set Control

Set Remote

Process

1

In Example:

Process = Stick (Using Remote On/Off)

Range = 110 to 390 A DC

Min = 110 A DC

Max = 390 A DC

Max (390 A DC)

Min (110 A DC)

In Example:

Process = TIG (Using Remote On/Off)

Range = 35 to 320 A DC

Percentage Of Range = 50%

Min = 35 A DC

Max = About 178 A DC (50% of 35 to 320)

Max (178 A DC)

Min (35 A DC)

Advertising
This manual is related to the following products: