OM-4429 Page 20

SECTION 5 − INSTALLATION

install3 2007−04 − Ref. 800 652 / Ref. 800 477-A / 803 274 / 804 712

!

Always securely fasten weld-

ing generator onto transport

vehicle or trailer and comply

with all DOT and other applica-

ble codes.

!

Always ground generator

frame to vehicle frame to pre-

vent electric shock and static

electricity hazards.

!

If unit does not have GFCI re-

ceptacles, use GFCI-protected

extension cord.

!

Do not install unit where air

flow is restricted or engine

may overheat.

.

See Section 4-2 for lifting eye rat-
ing.

.

See Section 5-3 for mounting in-

formation.

Grounding:
1

Equipment Grounding Terminal

(On Front Panel)

2

Grounding Cable (Not Supplied)

3

Metal Vehicle Frame

Connect cable from equipment

ground terminal to metal vehicle

frame. Use #10 AWG or larger insu-

lated copper wire.

.

Electrically bond generator
frame to vehicle frame by met-

al-to-metal contact.

!

Bed liners, shipping skids,

and some running gears insu-

late the welding generator

from the vehicle frame. Al-

ways connect a ground wire

from the generator equipment

grounding terminal to bare

metal on the vehicle frame as

shown.

GND/PE

1

2

3

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

Movement

5-1. Installing Welding Generator

OR

OR

Grounding

OR

Location/Airflow Clearance