OM-230 032 Page 26

5-5.

Voltage Sensing Lead And Work Cable Connections For Multiple Welding Arcs

A. Bad Setup

Ref. 804 528-A

1

Welding Power Source

2

Electrode Cable

3

Feeder Cable

4

Work Cable

5

Voltage Sensing Lead

6

Wire Feeder

7

Workpiece

This arrangement is a bad setup due to
sensing leads being directly in the current
flow path of the welding arc. Interaction
between welding circuits will affect voltage
drop in the workpiece. The voltage drop

across the workpiece will not be measured
correctly for the voltage feedback signal.
Voltage feedback to the welding power
sources will not be correct at either sense
lead and result in poor arc starts and arc
quality.