23.11 Disconnecting the remote session

To disconnect the session, on the Toolbar, click

. The Login box appears. You

can re-login or close the browser window.

24. Troubleshooting - Restoring factory defaults

Section

21 on page 17 explained how to restore factory settings from the Web

interface. When you cannot access the system e.g. you have forgotten the
Username or Password, you can restore factory defaults from the IP Control unit.

To restore factory defaults:

1. Press and hold down the Go-Local button for 3-4 seconds while powering up

the IP Control. The device boots up in safe mode.

2. Wait until the unit finishes booting.

3. Login with the default IP address of the unit:

http://192.168.0.155/config

. (Do

not start the address with https). The Login box appears see Figure 23.

Figure 23 Login box

4. Type username: admin , password: SAFEmode. (Case sensitive). This

username and password works only after the reset procedure described above. A
menu appears.