Initialize, Calibration, Initializing – Marantz DLPTM VP-12S3/VP-12S3L User Manual

Page 42: Color temperature adjustment

Advertising
background image

ENGLISH

After replacing the lamp or in other cases where the lighting
changes, color temperature can be adjusted using the included
color temperature sensor. In the adjustment procedure, you
must first initialize the sensor itself before adjusting color
temperature. It takes about 10 minutes from when the power to
the projector is activated for the lamp’s brightness to stabilize.
Wait for lamp brightness to stabilize before adjusting color
temperature.

1.

Connect the cable of the color temperature sensor to the
RS-232C port.

2.

Press the

MENU

button and select “Color Temp.

Calibration” from the MENU screen. Press the

2

button.

The below message appears on the screen.

3.

Use the

1

and

2

buttons to select “Yes” and press the

ENTER

button. The below message appears on the

screen.

Before pressing the

ENTER

button, turn the color

temperature sensor over on its dark side as shown in the
below figure, to prevent outside light from penetrating to
the sensor’s condenser.

Press "Enter" to start

Initialize

Press "Enter" to exit

Calibration

Color Temperature Adjustment

36

Condenser

4.

Press the

ENTER

button. The below message appears

on the screen for a few seconds as the sensor is being
calibrated.

5.

Turn the lens shift knob until bringing the position of the
projected image (lens shift position) to the center of the
screen.

Note:

Unless the lens shift position is brought to the center of the
screen, color temperature cannot be correctly adjusted.
As a yardstick for centering the lens shift position, the lens
shift knob can turn 11 times from one end of the lens shift
range to the other. Therefore, turn the knob completely to
one end and then return it about 5 1/2 turns.

6.

Fit the color temperature sensor onto the lens and press
the

ENTER

button. Color temperature adjustment starts

and the projector’s WARNING and STANDBY indicators
begin flashing simultaneously.

When installed on a tabletop

When installed on a ceiling

Initializing...

Attach the color temperature sensor
so that the cable is to the bottom side
of the projector.

Attach the color temperature sensor so that the
cable is to the bottom side of the projector.

Advertising