AGILE 5250 ALLY User’s Guide and Reference

Page 1-20

6 — Alternate Host Modes

The mode selection tells the 5250 ALLY what to do with the data it

receives from the alternate host. This should be set to Transparent (the

default) except for diagnostic purposes.

0. IBM printer emulation.
1. SCS dump.
2. Xerox 275 twinax protocol converter emulation.
4. Transparent (default).
5. Hex dump.

To select a mode, press the MODE button on the 5250 ALLY front panel

until the LED reads “6.” After two seconds, the LED will display an

underscore (_). Then press the MODE button until the LED displays the

number of the appropriate mode (0-5). After two seconds, the mode will be

changed and the unit will return to Normal Operating Mode.

7 — Alternate Host Timeout

When the alternate host port has stopped using the printer port for a user-

configurable period, the 5250 ALLY considers the printer port available

for the twinax port. The timeout period should be as short as possible to

prevent too much time from being wasted between print jobs from the

different sources, but not so short that a job from one source could

interrupt a job from the other source.
The following timeout values are available from the 5250 ALLY front

panel. The timeout period may need to be increased when running

complex graphic applications that take time during printing to compute the

image. Some applications may require timeout values as large as one

minute.

0. 1 second
1. 5 seconds (default)
2. 10 seconds
3. 15 seconds
4. 30 seconds
5. 45 seconds
6. 1 minute