12-2

SA-1100

Developer’s Manual

DC Parameters

12.2

DC Operating Conditions

Table 12-2

lists the functional operating dc parameters for the SA-1100.

Table 12-2.

SA-1100 DC Operating Conditions

Symbol

Parameter

Min

Nom

Max

Units Notes

Vihc

†

IC input high voltage

0.8

×

VDDX

—

VDDX

V

1, 2

Vilc

†

IC input low voltage

0.0

—

0.2

×

VDDX

V

1, 2

Vohc

OCZ output high voltage

0.8

×

VDDX

—

VDDX

V

1, 3

Volc

OCZ output low voltage

0.0

—

0.2

×

VDDX

V

1, 3

Iohc

High-level output current

—

—

– 2

mA

—

Iolc

Low-level output current

—

—

2

mA

—

Ta

Ambient operating temperature

0

—

70

°C

—

Iin

IC input leakage current

—

10

—

µA

—

Ioh

Output high current

(Vout = VDD – 0.4 V)

—

2

—

mA

—

Iol

Output high current

(Vout = VSS + 0.4 V)

—

2

—

mA

—

Cin

Input capacitance

—

5

—

pF

4

ESD

HBM model ESD

—

1

—

KV

—

NOTES:

1. Voltages measured with respect to VSS.
2. IC – CMOS-level inputs (includes IC and ICOCZ pin types).
3. OCZ – Output, CMOS levels, tristateable.
4. Parameter guaranteed by design

†

Not tested at this time