.PANEL

panel_name

protect_cc
skip_cc

variable_pair
text
variable_cc

unprotect_cc

variable_cc

field_length

variable_pair

.PANEL

Operands

panel_name

specifies the panel being defined. It must be one to eight characters in length and follow the rules for
REXX File System file names. (See Chapter 19, “REXX/CICS File System,” on page 257, for more
information.)

Note: The panel_name must be the same as the RFS file name. The complete RFS file name should

be panel_name.PANSRC.

protect_cc

specifies the protect field control character.

skip_cc

specifies the skip field control character.

variable_pair

specifies the variable control character followed by the variable name. (There cannot be a space
between them.)

text

displayable characters.

variable_cc

specifies the variable identifier control character.

unprotect_cc

specifies unprotect control character.

field_length

specifies the explicit input field length value.

Panel Generation and Panel Input/Output

Panel definition can be done outside the REXX environment; however, panel generation and input/output
is performed in a REXX exec or in the REXX interactive environment. The REXX interactive environment
is an ideal place to test the initial panel development. To test display the panel use the TEST panel
command. This displays the panel with no panel object file created. Also, there is no substitution for the
variables on the panel. To create the panel object use either the GENERATE, SEND, or the CONVERSE
panel commands. Use the FILE keyword to explicitly state what directory in RFS to find the panel source,
or you can let it default to the current directory. The panel source name must have the panel name as the
file name and 'PANSRC' as the file type. The panel object is created and filed in the same directory as the
panel source with the file name equal to the source file name and with a file type of 'PANOBJ'.
GENERATE creates the panel object and does not display the panel. SEND creates the panel object,
displays the panel, and attempts variable substitution. CONVERSE is similar to SEND with an implied wait
and receive.

Note: There are side affects of being in a REXX interactive environment. Several panel keywords act

differently: the cursor position on the SEND is ignored and keyboard lock is also ignored for SEND
and CONVERSE.

Panel Facility

Chapter 24. REXX/CICS Panel Facility

301