State codes and input codes, State codes – IBM SC34-5764-01 User Manual

Page 330

Advertising
background image

117

Variable value was too long and was truncated to fit output field

118

Text field was truncated. Check to see if explicit length did not force a subsequent field to overlay
another field.

119

Bad or missing panel command. It should be SEND, RECEIVE, CONVERSE, TEST, or END.

122

A modified field was received but it had no corresponding input field definition.

124

Empty received buffer. Clear, ENTER, and the PA keys will cause this.

125

File name is invalid

126

Field identifier for the ATTRIBUTE keyword was not found in the panel.

129

Too many arguments supplied with the command

130

SEND must be performed before a RECEIVE

131

Panel source has no panel definition. '.PANEL' was probably not in column 1 or did not have a
space after.

132

Keyword encountered is unknown

133

DROP asked for a control character not presently active

136

Continuation is in effect but end of source was encountered

137

Row or column specified is too large for the current display CURSOR() or POSITION() the likely
source of error.

138

Variable identifier control character was being defined and more than one stem name was listed.

139

More variable fields defined than listed in the control character definition.

140

Explicit input field value caused field to go past screen end

143

Panel name in file does not match the panel name in the panel runtime command.

144

Panel has more rows than the present screen allows

145

Panel has more columns than the present screen allows

State Codes and Input Codes

For return code 10 the reason code (in PAN.REA) has a special meaning. It consists of two 2-digit numeric
codes, the first number stating what keyword is being processed (state code) and the second number
stating the input that caused the error condition (input code). Use the location code (in PAN.LOC) to
determine which state code list and input code list to use.

For example:

RC = 10
PAN.REA = 0199
PAN.LOC = 1177

When you use the state code and input code lists for the 11xx location codes, the keyword being
processed was .DEFINE for state code 01 and the input code contained an unknown symbol for input
code 99.

State codes

State codes for 11xx location codes:
01

.DEFINE and control char

02

field type (protect/skip/unprotect)

03

color (red/blue/green/...)

04

Intensity (bright/normal/invisible)

05

Justify (left/right/nojustify)

Panel Facility

308

CICS TS for VSE/ESA: REXX Guide

Advertising