LOCATION

Always locate the ice machine where ambient temperatures will not fall below 50˚F nor rise above 100˚F.

CLEARANCE

Always make certain the machine and storage bin will fit through all doors and hallways leading to the final installation site.

When installed, there must be a 6-inch air clearance on rear, top and right side of Cornelius modular icemakers. Air intake and

discharge areas require a 6-inch clearance on all machines. Keep in mind when selecting the icemaker location that modular

machines may be stacked to increase production capacity as requirements grow.

UTILITY CONNECTIONS

Electrical, water and drain connections must be within 6 feet of machine location. All connections must meet national,

state and local codes.

ELECTRICAL REQUIREMENTS

Separate circuits, fuses and/or breakers are required for each icemaker or dispenser. Wire, fuse and circuit breaker sizes must be

calculated by a qualified electrician, based on the model’s specifications and must meet all national, state and local codes.

PLUMBING REQUIREMENTS

Ice machines must always be connected to the building’s cold water supply. For proper operation, water temperatures must not

exceed 45˚F-90˚F and pressure must be within 20-120 psi. Icemaker drain tubing must be a minimum of 1/2" I.D. Bin drain tubing must be

a minimum of 3/4" I.D. Icemaker and bin drains must be vented. Separate drain lines must be used for the icemaker and bin. Water-cooled

condenser drains must not be vented nor connected to icemaker or bin drain lines. All plumbing must meet national, state and local codes.

QUICK SIZING GUIDELINES

To determine the ice usage in a bar or restaurant, count the number of chairs for customers, multiply that number by 3 lbs. of ice

per bar stool and 1.5 lbs. per table seat. This should fulfill the customer’s needs, unless they are offering self-serve beverages or there is

an exceptionally large carry-out business. If the carry-out customer is at least one-third of the in-store business, add 1 lb. of ice for

each carry-out customer. Nursing home and hospital ice needs are calculated in much the same way. It is only necessary to count the

number of beds and refer to the following amounts: Hospitals need 10 lbs. of ice per bed; nursing homes require 6 lbs. of ice per bed.

Be sure to take into consideration other uses such as cafeterias and staff dining rooms, provided these areas do not have their own

icemakers. For churches or other places that use ice only once or twice a week, a small production machine on a large bin may be

adequate and economical to fulfill an occasional need for ice. However, if this is done and two meetings are scheduled one after the

other, the machine may not have time to adequately refill the bin before the start of the second engagement. When calculating total

daily ice usage make certain to include all anticipated ice usage. The final step is to consult the Cornelius specification sheets for the

model selected to determine its production capabilities under the operating conditions at the customer’s place of business.

MECHANICAL REQUIREMENTS FOR INSTALLATION OF

CORNELIUS ICE MACHINES AND STORAGE BINS

Customers

Application

Sizing Guide (daily ice use)

100

250

500

1,000

1,500

(figures below include a 20% safety factor)

Restaurant

1.5 lbs. ice per meal sold

180

450

900

1,800

2,700

Cocktail Bar

3.0 lbs. ice per seat

360

900

1,800

3,600

5,400

Water Glass

6 oz. ice per 12 oz. glass

45

113

225

450

675

Salad Bar

35 lbs. of ice per cubic foot

Beverage Only

5 oz. ice per 7-10 oz. cup

38

94

188

375

563

Beverage Only

8 oz. ice per 12-16 oz. cup

60

150

300

600

900

Beverage Only

12 oz. ice per 18-24 oz. cup

90

225

450

900

1,350

Guest Ice

5 lbs. per hotel room

600

1,500

3,000

6,000

9,000

Hotel Catering

1 lb. per person

120

300

600

1,200

1,800

Patient Ice

10 lbs. per patient

1,200

3,000

6,000

12,000

18,000

Cafeteria

1 lb. per person served

120

300

600

1,200

1,800

QUICK REFERENCE SIZING GUIDE BY CUSTOMER VOLUME