Series 300"xtreme, Series 322, Ari certified performance – Cornelius Series 50 User Manual

Page 5: Dimensions/capacity plumbing, Production chart, Specifications operating limits

Advertising
background image

C

U

B

E

R

S

5

Series 300"Xtreme"

ARI CERTIFIED PERFORMANCE

Ice Harvest

Potable Water

KWH

Condenser

Model

Rate

Use

Consumption

Water Use

Number

lbs. per 24 hrs.

per 100 lbs.

per 100 lbs.

per 100 lbs.

XAC322/XAC330

269

16.7

8.5

n/a

XWC322/XWC330

269

16.7

6.8

149

DIMENSIONS/CAPACITY

PLUMBING

Model

Nominal

Cabinet

Water

Electrical Service

Number

Capacity

Dimensions

Finish

Inlets/Outlets

Drainhose

Opening

XAC322

342 lbs.

22"w x 24

1

2

"d x 23"h

SS

3

8

" male flare

9

16

" I.D. x

3

4

" O.D.

7

8

" diameter hole

XAC330

342 lbs.

30"w x 24

1

2

"d x 23"h

SS

3

8

" male flare

9

16

" I.D. x

3

4

" O.D.

7

8

" diameter hole

XWC322

334 lbs.

22"w x 24

1

2

"d x 23"h

SS

3

8

" male flare

9

16

" I.D. x

3

4

" O.D.

7

8

" diameter hole

XWC330

334 lbs.

30"w x 24

1

2

"d x 23"h

SS

3

8

" male flare

9

16

" I.D. x

3

4

" O.D.

7

8

" diameter hole

PRODUCTION CHART

AIR-COOLED

WATER-COOLED

Water Temperature (˚F)

Water Temperature (˚F)

Air Temp (˚F)

50

70

80

Air Temp (˚F)

50

70

80

50

342

326

312

50

334

302

292

70

338

310

304

70

315

287

285

90

285

269

258

90

299

281

268

SPECIFICATIONS

OPERATING LIMITS

Model

Refrigerant

Standard

Circuit

Maximum

Shipping Operating

Ambient

Water

Water

Voltage

Number

Condenser

Type

Electrical

Capacity

Fuse Size

Weight

Weight

Temperature Temperature Pressure

Range

XAC322

Air-Cooled

R-404a

115/60/1

20

20

148 lbs.

123 lbs.

50°F-100°F

45°F-90°F

20-80 psi

110-126

XWC322 Water-Cooled

R-404a

115/60/1

20

20

144 lbs.

119 lbs.

50°F-100°F

45°F-90°F

20-80 psi

110-126

XAC330

Air-Cooled

R-404a

115/60/1

20

20

163 lbs.

136 lbs.

50°F-100°F

45°F-90°F

20-80 psi

110-126

XWC330 Water-Cooled

R-404a

115/60/1

20

20

155 lbs.

128 lbs.

50°F-100°F

45°F-90°F

20-80 psi

110-126

XAC322/XWC322

Rated in accordance with ARI Standard 810 -91.

31

3

4

"

22 "

71 "

23 "

Series 322†

SPECIFICATIONS

OPERATING LIMITS

Model

Refrigerant

Standard

Circuit

Maximum

Shipping Operating

Ambient

Water

Water

Voltage

Number

Condenser

Type

Electrical

Capacity

Fuse Size

Weight

Weight

Temperature Temperature Pressure

Range

AC322

Air-Cooled

R-404a

115/60/1

20

20

138 lbs.

122 lbs.

50°F-100°F

45°F-90°F

20-120 psi 110-126

WC322 Water-Cooled

R-404a

115/60/1

20

20

134 lbs.

118 lbs.

50°F-100°F

45°F-90°F

20-120 psi 110-126

ARI CERTIFIED PERFORMANCE

Ice Harvest

Potable Water

KWH

Condenser

Model

Rate

Use

Consumption

Water Use

Number

lbs. per 24 hrs.

per 100 lbs.

per 100 lbs.

per 100 lbs.

AC322

270

23.9

8.7

n/a

WC322

270

23.9

8.7

170

PRODUCTION CHART

AIR-COOLED

WATER-COOLED

Water Temperature (˚F)

Water Temperature (˚F)

Air Temp (˚F)

50

70

80

Air Temp (˚F)

50

70

80

50

359 lbs.

321 lbs.

312 lbs.

50

341 lbs.

300 lbs.

281 lbs.

70

333 lbs.

313 lbs.

277 lbs.

70

326 lbs.

289 lbs.

266 lbs.

90

305 lbs.

270 lbs.

249 lbs.

90

315 lbs.

270 lbs.

251 lbs.

AC322/B122AP

Rated in accordance with ARI Standard 810 -91.

†Limited lifetime warranty does not apply to this model.

22 "

29"

39

7

8

"

DIMENSIONS/CAPACITY

PLUMBING

Model

Nominal

Cabinet

Water

Electrical Service

Number

Capacity

Dimensions

Finish

Inlets/Outlets

Drainhose

Opening

AC322

359 lbs.

22"w x 23

1

2

" d x 16

3

8

" h

SS

3

8

" male flare

9

16

" I.D. x

3

4

" O.D.

7

8

" diameter hole

WC322

341 lbs.

22"w x 23

1

2

" d x 16

3

8

" h

SS

3

8

" male flare

9

16

" I.D. x

3

4

" O.D.

7

8

" diameter hole

16

3

8

"

23

1

2

"

Advertising