Series 2448, Series 1800"xtreme, Specifications operating limits – Cornelius Series 50 User Manual
Page 9: Production chart, Dimensions/capacity, Ari certified performance, Dimensions/capacity plumbing
C
U
B
E
R
S
C
H
U
N
K
L
E
T
S
9
Series 2448
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical Capacity Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
IRC2448
AC Remote*
R-404a
208-230/60/1
30
30
396 lbs.
335 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-235
IRC2448-3PH
AC Remote*
R-404a
208-230/60/3
30
30
396 lbs.
335 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-235
IWC2448
Water-Cooled
R-404a
208-230/60/1
30
30
388 lbs.
327 lbs.
50°F-100°F
50°F-90°F
20-120 psi 198-235
IRC2448/B1048SS
32"
48"
76"
PRODUCTION CHART
REMOTE AIR-COOLED
REMOTE WATER-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
2460 lbs. 2288 lbs.
2224 lbs.
50
2534 lbs. 2240 lbs. 2138 lbs.
70
2401 lbs. 2244 lbs.
2186 lbs.
70
2500 lbs. 2221 lbs. 2096 lbs.
90
2163 lbs. 2024 lbs.
1938 lbs.
90
2283 lbs. 2200 lbs. 2057 lbs.
DIMENSIONS/CAPACITY
Model
Nominal
Cabinet
Number
Capacity
Dimensions
Finish
IRC2448
2460 lbs.
48w x 23
1
⁄
2
" d x 28"h
SS
IRC2448-3PH
2460 lbs.
48w x 23
1
⁄
2
" d x 28"h
SS
IWC2448
2534 lbs.
48w x 23
1
⁄
2
" d x 28"h
SS
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Model
Rate
Use
Consumption
Water Use
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
IRC2448
2024 15.0
8.0
n/a
IRC2448-3PH
2024 15.0
8.0
n/a
IWC2448
2200
15.0
6.0
135
*Use Remote Condenser CR-2400.
28"
48"
Series 1800"Xtreme"
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
XAC1844 Air-Cooled
R-404a
208/230/60/1
30
30
367 lbs.
324 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1844 Water-Cooled
R-404a
208/230/60/1
30
30
345 lbs.
302 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1844 AC Remote*
R-404a
208/230/60/1
30
30
358 lbs.
315 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Model
Rate
Use
Consumption
Water Use
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
XAC1844
1600
14.5
7.3
n/a
XWC1844
1610
14.5
6.0
150
XRC1844
1600
14.5
7.3
n/a
Rated in accordance with ARI Standard 810 -91.
*Use Remote Condenser CR-2400.
XAC1844/B1048SS
44"
73 "
32
"
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
XAC1844
1947 lbs.
44"w x 24
3
⁄
4
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XWC1844
1700 lbs.
44"w x 24
3
⁄
4
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XRC1844
1947 lbs.
44"w x 24
3
⁄
4
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
25 "
PRODUCTION CHART
AIR-COOLED
WATER-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
1947 lbs. 1637 lbs.
1328 lbs.
50
1700 lbs.
1650 lbs. 1610 lbs.
50
1947 lbs.
1637 lbs.
1328 lbs
70
1928 lbs. 1619 lbs.
1309 lbs.
70
1660 lbs.
1630lbs.
1580 lbs.
70
1928 lbs.
1619 lbs.
1309 lbs.
90
1909 lbs. 1600 lbs.
1290 lbs.
90
1640 lbs.
1610 lbs. 1550 lbs.
90
1909 lbs.
1600 lbs.
1290 lbs.