Series 1400"Xtreme"
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
XAC1444 Air-Cooled
R-404a
208/230/60/1
30
30
317 lbs.
274 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1444 Water-Cooled
R-404a
208/230/60/1
30
30
295 lbs.
252 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1444 AC Remote*
R-404a
208/230/60/1
30
30
308 lbs.
265 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Model
Rate
Use
Consumption
Water Use
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
XAC1444
1275
14.3
6.8
n/a
XWC1444
1374
14.3
5.5
130
XRC1444
1275
14.3
6.8
n/a
Rated in accordance with ARI Standard 810 -91.
*Use Remote Condenser CR-1400.
XAC1444/B1048SS
44"
73 "
32
"
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
XAC1444
1630 lbs.
44"w x 24
3
⁄
4
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XWC1444
1505 lbs.
44"w x 24
3
⁄
4
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XRC1444
1630 lbs.
44"w x 24
3
⁄
4
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
25 "
C
U
B
E
R
S
8
Series 1200"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Model
Rate
Use
Consumption
Water Use
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
XAC1230
1019
14.6
6.5
n/a
XWC1230
1029
14.6
5.2
79.8
XRC1230
1019
14.6
6.5
n/a
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
XAC1230
Air-Cooled
R-404a
208-230/60/1
20
20
258 lbs.
229 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1230 Water-Cooled
R-404a
208-230/60/1
20
20
234 lbs.
205 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1230 AC Remote*
R-404a
208-230/60/1
20
20
247 lbs.
218 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
Rated in accordance with ARI Standard 810 -91.
*Use Remote Condenser CR-1200.
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
XAC1230
1177 lbs.
30"w x 24
1
⁄
2
" d x 28"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XWC1230
1062 lbs.
30"w x 24
1
⁄
2
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XRC1230
1177 lbs.
30"w x 24
1
⁄
2
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XAC1230/B1048SS
32
"
48 "
30 "
76 "
25” (water / remote
cooled)
28 " (air-cooled)
PRODUCTION CHART
AIR-COOLED
WATER-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
1177 lbs. 1137 lbs.
1070 lbs.
50
1062 lbs.
1055 lbs. 1042 lbs.
50
1177 lbs.
1137 lbs.
1070 lbs.
70
1143 lbs. 1098 lbs.
1039 lbs.
70
1059 lbs.
1046 lbs. 1027 lbs.
70
1143 lbs.
1098 lbs.
1039 lbs.
90
1076 lbs. 1019 lbs.
977 lbs.
90
1052 lbs.
1029 lbs. 1006 lbs.
90
1076 lbs.
1019 lbs.
977 lbs.
PRODUCTION CHART
AIR-COOLED
WATER-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
1630 lbs. 1505 lbs.
1470 lbs.
50
1505 lbs.
1391 lbs. 1362 lbs.
50
1630 lbs.
1505 lbs.
1470 lbs.
70
1537 lbs. 1416 lbs.
1380 lbs.
70
1473 lbs.
1385 lbs. 1346 lbs.
70
1537 lbs.
1416 lbs.
1380 lbs.
90
1340 lbs. 1275 lbs.
1198 lbs.
90
1409 lbs.
1374 lbs. 1315 lbs.
90
1340 lbs.
1275 lbs.
1198 lbs.