Series 800"xtreme, Series 1000"xtreme, Ari certified performance – Cornelius Series 50 User Manual
Page 7: Specifications operating limits, Production chart, Dimensions/capacity plumbing
Series 800"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Model
Rate
Use
Consumption
Water Use
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
XAC830
666
16.3
6.9
n/a
XWC830
700
17.4
5.6
116
XRC830
666
16.3
6.9
n/a
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum
Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
XAC830
Air-Cooled
R-404a
208/230/60/1
20
20
211 lbs.
182 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC830 Water-Cooled
R-404a
208/230/60/1
20
20
207 lbs.
178 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC830 AC Remote*
R-404a
208/230/60/1
20
20
223 lbs.
194 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
PRODUCTION CHART
AIR-COOLED
WATER-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
771 lbs.
752 lbs.
740 lbs.
50
780 lbs.
742 lbs.
715 lbs.
50
771 lbs.
752 lbs.
740 lbs.
70
747 lbs.
730 lbs.
712 lbs.
70
761 lbs.
724 lbs.
693 lbs.
70
747 lbs.
730 lbs.
712 lbs.
90
703 lbs.
666 lbs.
621 lbs.
90
736 lbs.
700 lbs.
676 lbs.
90
703 lbs.
666 lbs.
621 lbs.
PRODUCTION CHART
AIR-COOLED
WATER-COOLED
REMOTE AIR-COOLED
Water Temperature (˚F)
Water Temperature (˚F)
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
Air Temp (˚F)
50
70
80
50
950 lbs.
901 lbs.
890 lbs.
50
959 lbs.
916 lbs.
873 lbs.
50
950 lbs.
901 lbs.
890 lbs.
70
918 lbs.
877 lbs.
860 lbs.
70
939 lbs.
904 lbs.
869 lbs.
70
918 lbs.
877 lbs.
860 lbs.
90
854 lbs.
830 lbs.
799 lbs.
90
900 lbs.
887 lbs.
861 lbs.
90
854 lbs.
830 lbs.
799 lbs.
XAC830/B842SS
Rated in accordance with ARI Standard 810 -91.
*Use Remote Condenser CR-800.
25 "
32
"
30 "
42 "
73 "
C
U
B
E
R
S
7
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
XAC830
771 lbs.
30"w x 24
1
⁄
2
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XWC830
780 lbs.
30"w x 24
1
⁄
2
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XRC830
771 lbs.
30"w x 24
1
⁄
2
" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
Series 1000"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
KWH
Condenser
Model
Rate
Use
Consumption
Water Use
Number
lbs. per 24 hrs.
per 100 lbs.
per 100 lbs.
per 100 lbs.
XAC1030
830
13.2
7.0
n/a
XWC1030
887
13.2
5.5
112.7
XRC1030
830
13.2
7.0
n/a
SPECIFICATIONS
OPERATING LIMITS
Model
Refrigerant
Standard
Circuit
Maximum
Shipping Operating
Ambient
Water
Water
Voltage
Number
Condenser
Type
Electrical
Capacity
Fuse Size
Weight
Weight
Temperature Temperature Pressure
Range
XAC1030 Air-Cooled
R-404a
208/230/60/1
20
20
226 lbs.
197 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XWC1030 Water-Cooled
R-404a
208/230/60/1
20
20
215 lbs.
186 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XRC1030 AC Remote*
R-404a
208/230/60/1
20
20
225 lbs.
196 lbs.
50°F-100°F
45°F-90°F
20-80 psi
198-253
XAC1030/B1048SS
Rated in accordance with ARI Standard 810 -91.
*Use Remote Condenser CR-1200.
32
"
48 "
30 "
73"
DIMENSIONS/CAPACITY
PLUMBING
Model
Nominal
Cabinet
Water
Electrical Service
Number
Capacity
Dimensions
Finish
Inlets/Outlets
Drainhose
Opening
XAC1030
950 lbs.
30"w x 25" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XWC1030
959 lbs.
30"w x 25" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
XRC1030
950 lbs.
30"w x 25" d x 25"h
SS
3
⁄
8
" male flare
9
⁄
16
" I.D. x
3
⁄
4
" O.D.
7
⁄
8
" diameter hole
25"