26

90914

YES

NO

2.E LOW ICE PRODUCTION

IS

WATER LEVEL

NORMAL?

IS

WATER TEMP.

HIGH?

IS

AMBIENT TEMP.

HIGH?

IS

ICE THIN?

CHECK WATER ITEMS IN 2.A.

NORMAL EFFECT. INSTALL

REMCOR PRE-COOLER TO

INCREASE CAPACITY.

NORMAL EFFECT. ARRANGE

FOR LOWER AMBIENT AIR

TEMP. IF POSSIBLE.

GO TO 2.C.

CHECK REFRIGERATION

SYSTEM.

NO

NO

NO

YES

YES

YES