Cornelius SID851A/250S User Manual
Page 30
Advertising
27
90914
YES
2.F POOR ICE QUALITY
NO
YES
IS
ICE CLOUDY?
IS
ICE SOFT?
1. CHECK AIR PUMP.
2. CHECK ADJUSTMENT OF TIMER CAM #4. (WATER
PUMP)
3. CHECK TIMER SWITCH #4.
4. CHECK WATER DUMP VALVE.
5. CHECK WATER FILTER.
6. INCREASE WATER DUMP BY ADJUSTING TIMER
CAM #4.
7. INSTALL ADDITIONAL WATER TREATMENT DE-
VICES FOR SPECIFIC PROBLEM WATER.
DONE
NO