IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of water-related

service problems, a water filter should be installed. Remcor recommends the use of one of the

following basic systems:

1. Everpure, Inc.

2. System IV

660 No. Blackhawk Drive

16632 Burke Lane

Westmont, IL 60559

Huntington Beach, CA 92647

(708) 654-4000

(714) 842-4221

Insurlce Twin System #9320-42

Basic Water System #B1000

For specific recommendations on these filter systems for your local conditions, consult with a distributor in your

area or contact the filter manufacturer.

Models SID851/250S & SID851/250S-B

Connect two (2) 3/4?IPS (or equal) drain lines to the 3/4?threaded drain connections at the lower rear of the

unit. These lines must pitch downward to an open drain and must contain no traps or improper drainage will

result.

Model SID851/250S-BC

A 1?OD tubing drain elbow is provided at the bottom of the unit for the sink drain. Connect this elbow to a 7/8?

ID plastic drain tube.

A 3/4?IPS threaded drain connection for the ice maker is also provided at the bottom of the unit. Connect this

to a 3/4?IPS drain line (or equal).

These lines must pitch downward to an open drain and must contain no traps or improper drainage will result.

NOTE: In areas where consistently warm water temperatures are encountered, the use of a Remcor Pre-

Cooler in the water line is recommended to maximize the ice production of this unit. Contact Remcor

for more information on this product.

2. Electrical

A 4 x 2 junction box is located at the rear of the unit for the supply hook-up. Connect the ice maker to its

own circuit per the national electric code and local code. See SPECIFICATIONS for ampacity and fuse

size.

IMPORTANT: The wire size must be adequate for the ampacity rating, and the supply voltage must be

within a range of ± 10% for proper ice maker operation.

NOTE: The units require a 3 wire system plus earth ground for proper operations.

FIGURE 1. ELECTRICAL WIRING INSTALLATION INSTRUCTIONS

115/208-230V

1 PHASE

60 HERTZ

SUPPLY CONDUIT

BLACK (HOT)

RED (HOT)

WHITE (NEUTRAL)

GREEN (GROUND)